There are two stages
to configuring the SafeDial+ for use with the Multitech MTA128ST
TA - configuring
the Multitech and configuring the SafeDial+.
Configuring the Multitech MTA128ST
In order to get the Multitech MTA128ST to work with the SafeDial+
there is a certain amount of configuration that needs to be done
to the TA. To do this connect to the TA using the RS232 cable supplied.
Attach the DB25 way to the back of the TA and attach the DB9 way
to a free COM port on your PC (COM2 is used in this example).
Connect to the COM port which your TA is connected to using HyperTerminal
with the following settings:
 Type
AT a few times to make sure that you are connected. The LS (power)
and TR (Terminal Ready) LEDs should be lit on the TA.
Cut and paste the following string into the terminal window:
at&f7s0=0s52=0s59=0!z=8%e5&w0z
and hit enter. You should get an OK back after a few seconds:
Click
on picture thumbnail to view diagram
This string is a concatenated list
of commands - you do not need to know their meaning
but here they are for reference:
at&f7 = Reset the unit to default configuration.
ats0=0 = Turn off auto answer
ats52=0 = Turn off auto protocol detect
ats59=0 = Turn off dynamic bandwidth allocation
at!z=8 = Use the Softbond protocol
at%e5 = Use +++ escape sequence
at&w0 = Save the config to NVRAM and boot
from this profile
atz = Soft reset
There is also a menu driven configuration option
which can be entered with the command at@config. This can be useful for checking that the parameters
have been installed correctly.
This completes the configuration of the TA.
The next section deals with configuring the SafePort.
Configuring the SafeDial+
Disconnect the DB9 connector from the COM port
of your PC and connect it to the DB9 male connector
on the black cable supplied with the SafeDial+.
This cable has a DB9 male connector at one end
and a 15 way FCI connector at the other end and
is used for interfacing with communication devices
other than the Thales modem. Connect the 15 way
connector to the SafeDial+.
Insert the SafeDial+ into the PCMCIA slot. The
SafeDial+ will be allocated a COM port when it
is recognised by Windows (if you don't know which
COM port it is look in the modems section in
control panel)
Start HyperTerminal and connect to the specified
COM port with the following settings:

You should be able to send at
commands to the SafeDial+. Send the commands
at$sz=z
at$zz
and
at$sb=115200
If you want to check the values assigned you
can do so with the commands at$sz? and at$sb?
The purpose of doing this is that when the SafeDial+
initialises under Windows it sends the command
atf0 to the attached communications device -
this means "reset to factory default configuration".
The at$sz=z command tells the attached device
to undergo a soft reset which means the TA will
then boot from its saved profile therefore recovering
all the previously applied settings. The at$sb=115200 set the baud rate of the DTE interface to 115200bps.
It is very important that these options are
set on the SafeDial+ - without them the ISDN
connection will not work. Remember also that
if you ever replace your SafeDial+s and/or Multitech
TAs then this configuration procedure will need
to be repeated on the new equipment.
This completes the configuration of the SafeDial+
and the SafeDial+ can now be used to make a call
using Dial Up Networking. Some points to note
here;
- You make a call using either one or two ISDN
channels (64 or 128 kbps). To do this under
Dial Up Networking you dial either one or two
numbers
(see below). Depending on the configuration
of your ISDN network this may be the same number
twice or two different numbers. When dialling
two numbers they are joined together by the & symbol.

-
Also remember that you need to
set the SafeDial+ port speed to 115200bps
under Windows:
Return to the start page...
|