Commissioning Guidelines for UKG Datacryptor® Link E1 Units
 
Page 1 / 2

9. Removing force standby after Datacryptor® power outage
Refer to diagram showed in Section 8.

Run DUN and Element manager on the management laptop/PC
Double click icon for Datacryptor® that has suffered power outage. This will launch FPV.

Click the Login button, you will now be prompted for a user certificate/disk. Insert user 0(recommend that user 0 is always used for Cryptomanager). You will not need the CESG CA disk as this is stored by Cryptomanager.

During the login session a dialogue box will appear stating that this unit has just powered up and do you wish to enable data transfer. Select Yes to enable data transfer. This process is referred to as
‘ taking unit out of forced standby mode’.

Logout out and close down FPV, Element manager and DUN.

10. Loading New dated CESG key material onto Datacryptor® Link E1 unit
This process is required when existing unit certificate key material has expired(or is about to expired).
Connect Laptop/PC to Datacryptor® using a serial 9-way cable as shown below. Apply power to the Datacryptor® , run DUN and Key manager( you will be prompted to enter the Datacryptor® control port address, this is 2.2.2.2).


Click on picture thumbnails to view diagrams


Select Install Cert and insert CESG user certificate disk( use the same user disk number as the previously expired disk number), proceed to load user certificate onto Datacryptor®.
Close down Key manager and DUN.

You will not need the CESG CA disk since this has a three year lifetime.
When this expires you will need to load both new dated CA and new dated user certificate/disk.

 